GETTING STARTED WITH WINPEP 7
MakeRun and Your Dyno Electronics
Version 2 WinPEP 7 User Guide
3-13
TROUBLESHOOTING THE DYNO ELECTRONICS
1Close WinPEP 7.
2 Verify the serial cable is connected to the dyno electronics. Unplug the cable and
plug it back in.
3 Verify the serial cable is connected to the computer. Unplug the cable and plug it
back in.
4 Verify the dyno electronics is on and the green power LEDs on all the modules are
illuminated bright and equally.
Note: A dim green light may indicate a blown fuse. Refer to “Replacing the Fuses
in the Dyno Electronics”.
5 Launch WinPEP 7.
6 Repeat the steps for connecting the dyno electronics.
Note: If you have tried these steps and your dyno electronics is still not
communicating with your computer, verify that the file Data7.cfg exists in your
WinPEP software installation directory.
REPLACING THE FUSES IN THE DYNO ELECTRONICS
The CPU module uses two fuses while the other modules use one fuse.
Hazardous voltage. To avoid risk of electrical shock, disconnect all power to
the dyno electronics.
1 Gently remove the fuse holder from the back of the module.
2 Replace the fuse with a fuse type listed below.
3 Firmly replace the fuse holder in the back of the module.
For continued protection against risk of fire, replace only with a fuse of the
same type and having the same electrical rating.
part number fuse description module used with
54210020 Fuse, 1/4A, 250V, 5mm x 20mm CPU module
54210300 Fuse, 3A, 250V, 5mm x 20mm, FA CPU module
54210100 Fuse, 1 AMP, 250V, 5mm x 20mm I/O module, RPM module, and
Atmospheric Sensing module