WinPEP 7 User Guide
APPENDIX D
Analog Channel Configuration
D-6
EDITING A GAUGE
You will need to either create a new gauge or edit an existing gauge to represent your
analog channel. For this example, we will edit an existing gauge.
For more detailed information on creating a gauge, refer to “Creating and Editing
Gauges (Templates)” on page 6-12.
1 Verify you are in Advanced Mode. To change the user level click
Tool s
!
Environment Options and click on the General tab.
2 If you are not already there, go to the MakeRun screen. Click the Make Run
button . The last template used is automatically loaded.
3Click the Edit Mode button . You cannot edit gauges unless you are in Edit
Mode.
4 Right click on the gauge and choose Gauge Properties.
5 The Gauge Property Editor dialog box will appear.
Each type of gauge has a slightly different dialog box, but most share the same
properties.
6 Select the analog channel you created earlier from the Data Channel drop down
list.
The analog channel selected automatically appears in the Upper Title and on the
gauge.
Note: You must be connected to the dyno electronics and the Analog Module
must be installed for the list of analog channels to be available.