WinPEP 7 User Guide
APPENDIX G
G-4
11 Click Get Supported PIDs. The PIDs will be acquired from the vehicle.
You will see an extensive list of PIDs, but only the items with a “Y” before the
description are available for your particular vehicle.
12 Click Show Supported to narrow down the list.
13 Select the PIDs to be recorded during the dyno run.
14 Click Show Selected to display the selected PIDs.
15 If you would like to save this selection list as the default each time you use
WinPEP, click Save As Default.
Note: If an error occurs when you click Save As Default, you will need to modify a
file that resides in the root of WinPEP 7.
•Browse to C:\Program Files\WinPEP 7 and locate the file
PredatorPIDs.txt.
Right click on the file and select Properties.
Under Attributes, deselect Read Only. This will allow WinPEP to write to
this file, and allow you to use the Save As Default feature.
Figure G-3: DiabloSport Predator Configuration—Select PIDs
show supported
get supported PIDs
PIDs with “Y
show selected
save as default